CL-103

Provides gateway control, bridging and filtering multiple CAN networks. Creates a firewall between networks.
Inputs
2
Outputs
1
Current
0.5A PWM output
CAN
3 plus 4 other comm ports

Product Specifications

Hardware

Overview

16-bit HCS12X Microcontroller running at up to 50 MHz

MCU

S12XDP512

Flash

512 KB

RAM

32 KB

interfaces

CAN

3x J1939 CAN ports

USB

USB to Serial

Mechanical

Housing Material

Black Box: PA66 GF15Nylon 66 / 15% Glass Fibers)Clear Box: Ultem

Installation

Panel mount

Connectors

DTM06-12SA DTM06-12SB WM-12S (wedge) – Two needed (one per connector) 0462-201-20141 20AWG sockets 0413-204-2005 Sealing Plugs – Unused pins are required to be sealed to maintain module sealing

Dimensions

4.00″ x 4.68″

weight

~0.50 lbs

contacts

  • 20 AWG: 0462-201-20141
  • 16-18 AWG: 0462-005-20141

Plugs

0413-204-2005 Sealing Plugs

Wire Size

20AWG or 16-18AWG

Mounting & Torque

1/4″ or M6 Fastener62-88 in-lb

Indicators

1x Green Power1x Red Status

Electrical

Operating Voltage

8-32VDC

Key Switch

Yes

Max I/O Available

2/1

Product Ratings

IP Class

IP67IP6K9K

EU/CE Compliance

CE Marked

Temperature Range

  • Operating: -40C to +70C
  • Storage: -40C to +85C

Related Products

HED's T27 Telematics Module

CL-T27

Provides the ability for remote updates & diagnostics with over-the-air programming (OTA) and flexible applications tools.
Inputs
2
Outputs
1
Current
300mA
CAN
2

Ready To Get Started?

Connect with our team of experts to discuss your project and discover how HED can provide tailored control solutions for your vehicles.