CL-307

A compact module typically used for hydraulic solenoid control to maintain constant speed and flow.
Inputs
5
Outputs
8
Current
2A PWM outputs
CAN
1

Product Specifications

Hardware

Overview

16-bit HCS12X Microcontroller running at up to 50 MHz

MCU

S12XS128

Flash

128 KB

RAM

8 KB

interfaces

CAN

1x J1939 CAN port

Mechanical

Housing Material

Black Box: PA66 GF15Nylon 66 / 15% Glass Fibers)Clear Box: Ultem

Installation

Panel mount

Connectors

DTM06-12SC DTM06-12SD WM-12S (wedge) – Two needed (one per connector) 0462-201-20141 20AWG sockets 0462-005-20141 16-18AWG sockets 0413-204-2005 Sealing Plugs – Unused pins are required to be sealed to maintain module sealing

Dimensions

4.65″ x 5.25″ x 1.40″

weight

~0.56 lbs

contacts

  • 20 AWG: 0462-201-20141
  • 16-18 AWG: 0462-005-20141

Plugs

0413-204-2005 Sealing Plugs

Wire Size

20AWG or 16-18AWG

Mounting & Torque

1/4″ or M6 Fastener62-88 in-lb

Indicators

1x Green Power1x Red Status

Electrical

Operating Voltage

8-32VDC

Key Switch

No

Max I/O Available

5/8

Inputs

2x inputs software configurable as switch to ground or frequency 3x 10-bit analog inputs

Outputs

8x 2-wire constant current 2A PWM outputs configured as 4 complimentary pairs

Product Ratings

IP Class

IP67

EU/CE Compliance

No

Temperature Range

  • Operating: -40C to +70C
  • Storage: -40C to +85C

Downloads

READY TO DOWNLOAD?

PFS-CL307-A1

CL-307 technical information on Inputs, Outputs, CAN, Operating Voltage and other features.

Deutsch Box – 2 Connector STEP

CL-103 Step file

CL307-103-B2 Data Sheet

CL-307 module I/O and features

CL307-102-B2 Data Sheet

CL-307 module I/O and features

CL307-101-C2 Data Sheet

CL-307 module I/O and features

CL307-100-C2 Data Sheet

CL-307 module I/O and features

Related Products

CL-450

A powerful body controller with high I/O and multiple CAN ports allowing a bridge to multiple CAN networks.
Inputs
36
Outputs
33
Current
3 A
CAN
3

CL-451

Compact and typically used to drive stacked valve drive sections or outputs condensed into a single location.
Inputs
17 (total I/O)
Outputs
16 (available)
Current
3 A
CAN
1

CL-4002

Primarily an output control module with input options used to drive valve and body outputs. Can be used as primary.
Inputs
10 (total I/O)
Outputs
Digital (8) / Analog (2)
Current
5 A
CAN
2

Ready To Get Started?